Walk-In / Drive-In Test Chambers
Walk-In / Drive-In Series Standard Features
Listed below are the standard features that are available
on Walk-In chambers.
Cabinet Features
Safety Release Latches are standard on all CSZ Walk-In Chambers
to prevent a user from being trapped inside the chamber.
Stainless Steel Interior
All liners are constructed from Type 304 brushed stainless
steel that is easy to clean. All seams are continuously heliarc
welded to form a hermetically sealed unit to prevent moisture
migration.
Chamber Exterior
The chamber exterior is constructed of formed sheet steel
for structural strength and finished with a durable powder
coat finish or textured polyurethane paint. Customer specified
paint combinations are available upon request.
Fog-Free Viewing Window
A multi-pane, heated window prevents condensation and allows
for product viewing.
Vapor Proof Lights
Vapor proof lights illuminate chamber workspace/product
and prevent moisture from penetrating the light fixture.
Instrumentation Features
 |
Touch
Screen Controller
The CSZ EZT-560i Touch Screen Controller includes unlimited
profiling each with 99 steps, looping, product monitor,
and data storage. |
Refrigeration Features
Refrigeration Pressure Gauges
Allows operating pressures to be continuously monitored and
provides early warning indicators in the event of a leak.
Zero Ozone Depletion Refrigerants
CSZ chambers utilize refrigerants which are environmentally
safe, non-flammable, non-explosive and have a Zero Ozone Depletion
Potential (ODP).
Humidity Features
Humidity Demineralizer Water Filter System
Demineralizer removes water impurities and minerals that can
harm your chamber. Cartridges will turn orange-brown when
used and are easily replaceable.
Electronic Humidity Sensor
CSZ uses an electronic, solid state humidity sensor on all
of their humidity chambers. These sensors are highly reliable,
accurate, and require minimal maintenance compared to the
old wet wick humidity system that requires a lot of maintenance.
Walk-In / Drive-In Series Optional Accessories
Listed below are the options that are available on Walk-In
chambers.
Cabinet Options
Additional Access Ports
Additional circular, square, or rectangular ports are available
in a variety of sizes. Ports may be placed on both sides of
the chamber for ease of cable routing.
Entry Ramp
Entry ramps with diamond trend plate floor are available
for easy loading of test items.
Oversize/Additional Doors
Oversize doors are available to for large test items
and full vehicle testing.
Reinforced Floor
Heavy gauge floor with optional diamond trend plate
is available for large loads.
Instrumentation Options
Windows-Based Software Package
CSZ EZ-Viewsoftware is available for monitoring and controlling
up to 20 chambers from any location.
Redundant Temperature Limit & Alarm
Provides essential failsafe over/under (hi/low) temperature
protection for your valuable test items.
IEEE-488 Computer Interface
A parallel interface can be provided for interface with IEEE-488
parallel instrument control buss. A standard IEEE-488 connector
is provided for easy connection to adjacent test equipment.
Hydro Carbon/Carbon Monoxide Monitor
Conveniently measures the level of hydrocarbons in
the air that are emitted from a vehicle.
Chart Recorders
A selection of one or two pen chart recorders are available
with a variety of pre-printed charts or self printing thermal
charts.
Running Time Meter
The optional run time meter includes a non-resettable display
which will accumulate the system running time for routine
maintenance and planning purposes.
Main Power Disconnect
Provides an additional level of safety by shutting down the
main power to the chamber prior to maintenance or repair.
Performance & Refrigeration Options
CO2/LN2 Boost Cooling
Boost cooling is available for applications that require a
fast pulldown rate.
CO2/LN2 Cooling Only
CO2/LN2 cooled chambers are available without mechanical refrigeration
for lower initial costs on applications requiring ultra low
temperatures down to
-300°F.
Remote Refrigeration
Allows the refrigeration system to be located approximately
50 feet away from the chamber. This option is commonly used
for labs with space restrictions or to minimize noise levels.
Refrigeration Sound Deadening
Although CSZ chambers are quiet operating, sound foam is available
as an option to further reduce the noise generated by the
refrigeration system. This option is commonly used in larger
chambers.
Humidity Options
*Recirculating Humidity Water Supply
For customers that do not have a dionized water supply, CSZ
provides a recirculating water system that collects condensate
from the chamber, filters it, and stores it in a reservoir
for reuse.
Low Relative Humidity
For tests requiring humidity levels below 10% RH, CSZ provides
an optional low humidity system for testing down to 5% RH.
Spare Water Demineralizer Cartridges
Additional demineralizer cartridges are available for overnight
delivery. Cartridges will turn orange-brown when used and
are easily replaceable.
|