CSZ Solar Panel Test Chambers Provide Up To 66% Energy Savings
Using CSZ’s patented Tundra® refrigeration system
provides the ability to test product down to -40°C with
a load and a single compressor where traditional test chambers
for solar panel testing require a cascade refrigeration system.
Documented energy savings of 47-66% were obtained by following
the test specifications below with CSZ test chambers and a
Fluke power monitoring system.
| Test Spec |
Energy Savings |
No. of Cycles/No. of Days |
Cost Savings |
| Temperature Cycling Test |
| IEC 61646 |
47% |
50 or 200 cycles 6 or 25 days* |
Up to $14.80 per day |
| IEC 61215 |
| Humidity Freeze Test |
| IEC 61646 |
65% |
10 cycles 10 days |
Up to 11.64 per day |
| IEC 61215 |
62% |
Up to $9.92 per day |
| Damp Heat Test |
| IEC 61646, IEC 61215 & IEC 62108 |
66% |
1,000 hours 42 days |
Up to $8.89 per day |
*Time based upon a chamber that meets that
max ramp rate requirements. Data compares the energy savings
of operating at 15HP cascade compared to a 10HP Tundra in
an empty chamber. Cost savings calculations based upon 13
cents per Kwh.
A total of $560 - $860
dollars can be saved
completing each of the above tests in a
CSZ chamber with Tundra system.
|